Smart charging

Control charging power through OCPP smart charging: set, list and clear charging profiles per station (purposes charger_max, tx_default and session; units W or A; time-of-use windows), ask the charger for its composite schedule, and cap a running session's power or current. Writes are charger messages: Idempotency-Key, 202 with an operation whose result carries the charger's answer, and charging_profile.accepted, .rejected and .cleared webhooks. What the charger reported it cannot take is refused before anything is sent. Reads require stations:read, writes stations:control. OCPP 1.6, 2.0.1 and 2.1.

9 endpoints